Page Banner

PT Blood Collection Tubes (9NC Sodium Citrate Anticoagulation Tubes)

PT tube is filled with 3.2% sodium citrate. The ratio for liquid sodium citrate to blood is 1:9. PET+PP tube features innovative tube geometry that minimises tube headspace and associated platelet activation to optimise APTT monitoring of untractionated heparin patients.

Features

  • How it works: Sodium citrate serves as the active ingredient. It combines with calcium ions in blood to inhibit the clotting process for anticoagulation.
  • Additive filling: The sodium citrate is filled by precise peristaltic pump dosing system.
  • The PET PT tube is packed with aluminum bag to keep the product stable.
  • Operation notice: Invert the tube 6-8 times immediately after blood collection to prevent blood clotting.

Product Specifications

ProductCap ColorMaterialSizeVolume
PT tube
9NC sodium citrate tube
BluePET/GLASS13x75mm1.8ml,2ml,2.7ml,
3ml,3.6ml,4ml,4.5ml
PET/GLASS13x100mm4.5ml,5ml
PET (Double layer)13x75mm2ml,3ml

Application

PT tube is used for coagulation tests, including clotting time (CT), prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (FIB), D-dimer (D-D) and prothrombin time ratio (PTR).

Why this product is chosen?

PT tubes use 3.2% sodium citrate to bind calcium and prevent blood clotting. The anticoagulation is reversible, which is essential for PT, APTT, D-Dimer and other coagulation tests. EDTA and heparin will interfere with these assays.

Frequently Asked Questions (FAQ)

A: Double-layer tubes are made of PET tube and PP tube. The outer PET layer maintains stable internal vacuum. The inner PP layer blocks water evaporation and prevents additive loss. This prevents deviation of test results caused by additive concentration variation from moisture loss.

A: Clot formation in anticoagulant tubes is mainly caused by insufficient mixing. If the tube is not inverted promptly or mixed inadequately after blood collection, partial blood fails to contact the anticoagulant and forms clots. This phenomenon does not indicate health problems of the patient.

Recommended operation: Gently invert the tube 6–8 times immediately after blood collection.

Explore Portfolio

Related Consumables & Needles

Multi-Sample Blood Collection Needles (Pen Needles)

Multi-Sample Blood Collection Needles (Pen Needles)

View Details
Flashback Blood Collection Needles (Flashback Chamber Needles)

Flashback Blood Collection Needles (Flashback Chamber Needles)

View Details
Safety Butterfly Blood Collection Needles (Retractable blood collection needles)

Safety Butterfly Blood Collection Needles (Retractable blood collection needles)

View Details
butterfly blood collection needles (venous winged sets)

Butterfly Blood Collection Needles (Soft-link blood collection needles)

View Details
QUICK ACCESS